Ettus USRP Family hardware

You can run OsmoTRX using the Ettus USRP family of devices.

All Ettus Research devices are supported.

Ettus Research Notes
USRP1 Requires legacy libusrp driver and clocking modification
USRP2 10 MHz external reference required
B100
B110
B200 GPSDO or 10 MHz external reference recommended
B210 Dual channel, 10 MHz external reference recommended
N200
N210
E100
E110

FIXME: More USRP specific information here

Ettus USRP B2x0

Ettus B2x0 output signal levels
band arfcn tx-attenuation signal level (dBm)
850 128 0 13.2
850 189 0 13.2
850 251 0 13.2
900 0 0 13.1
900 86 0 13.1
900 1023 0 13.1
1800 512 0 6.9
1800 698 0 6.9
1800 870 50 -42.0
1800 870 25 -16.7
1800 870 10 -2.1
1800 870 0 7.1
1800 885 0 6.9
1900 512 0 7.2
1900 661 0 7.3
1900 810 0 7.4

these values were measured by sysmocom on a agilent E4406 with an ettus B210