Project

General

Profile

Ettus USRP Family » History » Version 4

laforge, 06/13/2017 06:06 PM

1 2 laforge
h1. Ettus USRP Family hardware
2
3
You can run OsmoTRX using the Ettus USRP family of devices.
4
5 3 laforge
All Ettus Research devices are supported.
6
7 4 laforge
|*Ettus Research*|*Notes*|
8
|USRP1|Requires legacy libusrp driver and clocking modification|
9
|USRP2|10 MHz external reference required|
10
|B100||
11
|B110||
12
|B200|GPSDO or 10 MHz external reference recommended|
13
|B210|Dual channel, 10 MHz external reference recommended|
14
|N200||
15
|N210||
16
|E100||
17
|E110||
18 3 laforge
19 2 laforge
FIXME: More USRP specific information here
20
21
h2. Ettus USRP B2x0
22 1 roh
23
Ettus B2x0 output signal levels
24
|_.band |_.arfcn |_.tx-attenuation |_.signal level (dBm) |
25
|  850 | 128 |  0 |  13.2 |
26
|  850 | 189 |  0 |  13.2 |
27
|  850 | 251 |  0 |  13.2 |
28
|  900 |   0 |  0 |  13.1 |
29
|  900 |  86 |  0 |  13.1 |
30
|  900 |1023 |  0 |  13.1 |
31
| 1800 | 512 |  0 |   6.9 |
32
| 1800 | 698 |  0 |   6.9 |
33
| 1800 | 870 | 50 | -42.0 |
34
| 1800 | 870 | 25 | -16.7 |
35
| 1800 | 870 | 10 |  -2.1 |
36
| 1800 | 870 |  0 |   7.1 |
37
| 1800 | 885 |  0 |   6.9 |
38
| 1900 | 512 |  0 |   7.2 |
39
| 1900 | 661 |  0 |   7.3 |
40
| 1900 | 810 |  0 |   7.4 |
41
42
these values were measured by sysmocom on a agilent E4406 with an ettus B210
Add picture from clipboard (Maximum size: 48.8 MB)