Project

General

Profile

Bug #2715

"show trx" doesn't show missing RSL connection

Added by laforge 8 months ago. Updated 7 months ago.

Status:
Resolved
Priority:
Normal
Assignee:
Category:
A-bis RSL
Target version:
-
Start date:
12/06/2017
Due date:
% Done:

100%

Estimated time:
Spec Reference:

Description

The output of "show trx" looks identical whether or not the RSL connection is established by the TRX:


TRX 0 of BTS 0 is on ARFCN 871
Description: (null)
  RF Nominal Power: 23 dBm, reduced by 20 dB, resulting BS power: 3 dBm
  NM State: Oper 'Enabled', Admin 'Unlocked', Avail 'OK'
  Baseband Transceiver NM State: Oper 'Enabled', Admin 'Unlocked', Avail 'OK'
  ip.access stream ID: 0x00

basically, it only shows the OML point of view, and not the RSL point of view.

History

#1 Updated by laforge 7 months ago

  • Project changed from OpenBSC to OsmoBSC
  • Category deleted (libbsc)

#2 Updated by laforge 7 months ago

  • Category set to A-bis RSL

#3 Updated by laforge 7 months ago

  • Assignee set to msuraev

#4 Updated by msuraev 7 months ago

  • Status changed from New to In Progress
  • % Done changed from 0 to 70

Fix available in gerrit 5659.

#5 Updated by msuraev 7 months ago

  • Status changed from In Progress to Resolved
  • % Done changed from 70 to 100

Fix has been merged to master.

Also available in: Atom PDF

Add picture from clipboard (Maximum size: 48.8 MB)