Bug #2773
closed
`show hnb all` shows MCC 0 MNC 0 HNBAP ID 0 RUA ID 0 - check if they are correct
Added by lynxis over 6 years ago.
Updated over 6 years ago.
Description
e.g. the mcc is set to a valid id, but doesn't show up.
Is hnbap 0 + rua 0 also invalid?
Please re-check all 4 variable if they contains the correct values from the HNB
MCC + MNC are sent as id-PLMNidentity.
Unsure about HNBAP ID / RUA ID. The HNB sents a "id-CellIdentity" which might contains those information. haven't check the spec.
- Status changed from New to In Progress
- Assignee set to neels
- % Done changed from 0 to 90
https://gerrit.osmocom.org/5530 adds MCC MNC
The HNBAP and RUA SCCP stream IDs seem to actually be zero according to wireshark; there is code that is assigning them in hnbgw.c in hnb_read_cb():
switch (msgb_sctp_ppid(msg)) {
case IUH_PPI_HNBAP:
hnb->hnbap_stream = msgb_sctp_stream(msg);
rc = hnbgw_hnbap_rx(hnb, msg);
break;
case IUH_PPI_RUA:
hnb->rua_stream = msgb_sctp_stream(msg);
rc = hnbgw_rua_rx(hnb, msg);
break;
https://gerrit.osmocom.org/5532 changes the wording to "SCCP-stream:HNBAP=0,RUA=0"
- Status changed from In Progress to Resolved
- % Done changed from 90 to 100
Also available in: Atom
PDF