Project

General

Profile

Actions

Bug #2991

closed

OsmoBTS doesn't generate CCCH LOAD INDICATIONS

Added by laforge about 6 years ago. Updated about 6 years ago.

Status:
Resolved
Priority:
Normal
Assignee:
Category:
-
Target version:
-
Start date:
02/24/2018
Due date:
% Done:

100%

Spec Reference:

Description

Despite OsmoBSC setting the Load Indication Period to 1s over OML, and a paging load above the threshold, I don't see CCCH LOAD IND on RSL.

Actions #1

Updated by laforge about 6 years ago

  • Status changed from New to In Progress
  • % Done changed from 0 to 70

The load indication timer was started before the OML attribute for the load indication period has been set.

A patch has been written and is currently under testing.

https://gerrit.osmocom.org/6874

Actions #2

Updated by laforge about 6 years ago

  • Status changed from In Progress to Resolved
  • % Done changed from 70 to 100

merged

Actions

Also available in: Atom PDF

Add picture from clipboard (Maximum size: 48.8 MB)