Project

General

Profile

Actions

Feature #3277

closed

handover: for intra-cell re-assignment, use Assignment procedure, not Handover

Added by neels almost 6 years ago. Updated over 2 years ago.

Status:
Resolved
Priority:
High
Assignee:
Category:
-
Target version:
-
Start date:
05/17/2018
Due date:
% Done:

100%

Spec Reference:

Description

Handover Decision algorithms may decide to do a re-assignment within the same cell.
In practical tests, some time ago, I noticed that using the RR Assignment Command wasn't working here.
Hence we currently send an RR Handover Command referencing the same cell, which is kind of weird.

Now I saw one reason why Assignment doesn't work for handover: in bsc_api.c, in handle_ass_compl(),
we receive the RR Assignment Complete message and dispatch an SS_LCHAN signal S_LCHAN_ASSIGNMENT_COMPL.
However, throughout osmo-bsc, there is not a single handler for S_LCHAN_ASSIGNMENT_COMPL.

This might be another casualty from the split-off from osmo-nitb.

Anyway, it doesn't make sense to me that we send an S_LCHAN_ASSIGNMENT_COMPL,
while the remaining code triggers bsc_subscr_conn_fsm.c GSCON_EV_* events directly.

Fix: Actually handle RR Assignment Complete during handover,
and send RR Assignment Command instead of RR Handover Command for intra-cell HO.

This is not high priority, and should wait until after intra-BSC handover has rippled through the lchan allocation code.


Related issues

Has duplicate OsmoBSC - Feature #2949: use RR Assignment for Handover within a cellResolved02/16/2018

Actions
Actions

Also available in: Atom PDF