I'm seeing this during every RSL bring-up on my RBS2308:

<0017> input/dahdi.c:263 E1TS(0:1) TX: 0c 11 01 80 1e 01 27 17 55 06 19 8f 90 00 00 00 00 00 00 00 00 00 00 00 00 00 00 e5 04 00 6b 
<0017> input/dahdi.c:263 E1TS(0:1) TX: 0c 11 01 80 1e 02 27 17 59 06 1a 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ff e5 04 00 
<0017> input/dahdi.c:263 E1TS(0:1) TX: 0c 11 01 80 1e 0a 
<0017> input/dahdi.c:263 E1TS(0:1) TX: 0c 11 01 80 1e 0b 
<0017> input/dahdi.c:263 E1TS(0:1) TX: 0c 11 01 80 1e 29 
<0017> input/dahdi.c:263 E1TS(0:1) TX: 0c 11 01 80 1e 03 27 17 49 06 1b 00 00 62 f2 24 00 01 c9 03 05 27 5e 00 e5 04 00 29 2b 2b 2b 
<0017> input/dahdi.c:263 E1TS(0:1) TX: 0c 11 01 80 1e 04 27 17 31 06 1c 62 f2 24 00 01 5e 00 e5 04 00 2b 2b 2b 2b 2b 2b 2b 2b 2b 2b 
<0017> input/dahdi.c:263 E1TS(0:1) TX: 10 1a 1e 05 0b 00 12 06 1d 10 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 
<0017> input/dahdi.c:263 E1TS(0:1) TX: 10 1a 1e 0d 
<0017> input/dahdi.c:263 E1TS(0:1) TX: 10 1a 1e 0e 
<0003> abis_rsl.c:1237 (bts=0,trx=0) ERROR REPORT (cause=Service or Option not available [ 3f ])
<0017> input/dahdi.c:263 E1TS(0:1) TX: 10 1a 1e 06 0b 00 0c 06 1e 00 00 62 f2 24 00 01 27 ff 3b 

So I guess one of the BCCH / SACCH filling we send is not appreciated by the RBS2308.


Files

rbs2308-si5ter.pcap rbs2308-si5ter.pcap 1.26 KB laforge, 07/04/2020 07:12 PM
Actions #1

Updated by laforge over 3 years ago

  • File rbs2308-si5ter.pcap rbs2308-si5ter.pcap added
  • Subject changed from OM2K: abis_rsl.c:1237 (bts=0,trx=0) ERROR REPORT (cause=Service or Option not available [ 3f ]) to OM2K SI5ter: abis_rsl.c:1237 (bts=0,trx=0) ERROR REPORT (cause=Service or Option not available [ 3f ])
  • Priority changed from Normal to Low
  • % Done changed from 0 to 10

It seems we get this ERROR REPORT after sendign SI5ter. Attaching a pcap file.