open

Show BTS Channel Load on Ericsson BTS

Added by keith 8 months ago. Updated 8 months ago.

Status:
New
Priority:
Normal
Assignee:
-
Category:
Ericsson BTS
Target version:
-
Start date:
04/02/2021
Due date:
% Done:

0%

Spec Reference:

Description

On the RBS, the TRX NM State is always NULL.

This works around https://gerrit.osmocom.org/plugins/gitiles/osmo-bsc/+/refs/heads/keith/rbs_mo
to get the channel load showing up, but it is probably not the right patch.

Actions #1

Updated by keith 8 months ago

OsmoBSC# show trx
TRX 0 of BTS 0 is on ARFCN 246
Description: (null)
  RF Nominal Power: 40 dBm, reduced by 0 dB, resulting BS power: 40 dBm
  Radio Carrier NM State: Oper 'Enabled', Admin 'Unlocked', Avail 'OK'
  RSL State: connected
  Baseband Transceiver NM State: *Oper 'NULL'*, Admin 'Locked', Avail 'Power off'
  E1 Signalling Link:
    E1 Line 0, Type e1d: Timeslot 1, Mode RSL
    E1 TEI 0, SAPI 0
TRX 1 of BTS 0 is on ARFCN 250
Description: (null)
  RF Nominal Power: 40 dBm, reduced by 0 dB, resulting BS power: 40 dBm
  Radio Carrier NM State: Oper 'Enabled', Admin 'Unlocked', Avail 'OK'
  RSL State: connected
  Baseband Transceiver NM State: *Oper 'NULL'*, Admin 'Locked', Avail 'Power off'
  E1 Signalling Link:
    E1 Line 0, Type e1d: Timeslot 4, Mode RSL
    E1 TEI 1, SAPI 0
Actions #2

Updated by laforge 8 months ago

  • Category set to Ericsson BTS