Project

General

Profile

Actions

Bug #5174

closed

PowerUp fails after a very long delay: 17 seconds

Added by rousseau almost 3 years ago. Updated over 2 years ago.

Status:
Closed
Priority:
Normal
Assignee:
Target version:
-
Start date:
06/09/2021
Due date:
% Done:

0%

Spec Reference:

Description

I am using the simbank96 (remotely) and I have issues with some slots.

When the Power Up fails the reader answers after a very long delay of 17 seconds.
The pcscd trace contains:

12181476 [140119642187520] <- 00000F 80 00 00 00 00 07 3D 41 FE 00 
00000075 [140119642187520] commands.c:246:CmdPowerOn Card absent or mute
00000045 [140119642187520] commands.c:275:CmdPowerOn() Power up with 5V failed. Try with auto.
00000048 [140119642187520] -> 00000F 62 00 00 00 00 07 3E 03 00 00 
17178026 [140119642187520] <- 00000F 80 00 00 00 00 07 3E 41 FE 00 
00000090 [140119642187520] commands.c:246:CmdPowerOn Card absent or mute
00000035 [140119642187520] commands.c:275:CmdPowerOn() Power up with 1.8V failed. Try with 3V.
00000091 [140119642187520] -> 00000F 62 00 00 00 00 07 3F 02 00 00 
17177975 [140119642187520] <- 00000F 80 00 00 00 00 07 3F 41 FE 00 
00000069 [140119642187520] commands.c:246:CmdPowerOn Card absent or mute
00000046 [140119642187520] commands.c:275:CmdPowerOn() Power up with 3V failed. Try with 5V.
00000038 [140119642187520] ifdhandler.c:1252:IFDHPowerICC() PowerUp failed

I don't know if the card is faulty or if the problem is elsewhere. Electrical issue?
My problem is that a timeout of 17 seconds is very long.

I already reported a similar problem in https://osmocom.org/issues/4815. The timeout was changed from 60 seconds to 1.4 second.
I don't know why I get a 17 seconds timeout here.

I have the problem for the following readers (from pcsc_scan):

 Reader 9: sysmocom - s.f.m.c. GmbH sysmoOCTSIM [CCID] (6b44014933353553202020341b3815ff) 01 01
  Event number: 0
  Card state: Card inserted, Unresponsive card, 
 Reader 10: sysmocom - s.f.m.c. GmbH sysmoOCTSIM [CCID] (6b44014933353553202020341b3815ff) 01 02
  Event number: 0
  Card state: Card inserted, Unresponsive card, 
 Reader 15: sysmocom - s.f.m.c. GmbH sysmoOCTSIM [CCID] (6b44014933353553202020341b3815ff) 01 07
  Event number: 0
  Card state: Card inserted, Unresponsive card, 

These are slots 2, 3 & 8 of the second sysmoOCTSIM.