open

Training Sequence Code error on Handover into sysmobts

Added by keith 2 months ago. Updated 2 months ago.

Status:
New
Priority:
Low
Assignee:
-
Category:
-
Target version:
-
Start date:
10/01/2021
Due date:
% Done:

0%

Spec Reference:

Description

When handing over from osmo-bts-trx/osmo-trx-lms into sysmobts, I'm seeing

DL1C <0006> ../../../git/src/common/rsl.c:269 (bts=0,trx=0,ts=6,ss=0) This PHY does not support lchan TSC 0 != BSIC-TSC 7, sending NACK

Of course, then all lchans end up B0RKEN


Related issues

Related to OsmoBSC - Bug #5219: VTY cmd "bts 0 trx 0 timeslot 1 sub-slot 0 activate fr" fails on sysmobts with BSIC 10Resolvedpespin08/27/2021