Ericsson RBS2000 GPRS

This page collects some information regarding Ericsson RBS2000 GPRS support.

The fundamental difference between what we do so far (PCU co-located with BTS) and this architecture is that the PCU is co-located with the BSC!

In order to have (E)GPRS support using RBS2000, we need to solve the following parts:
  • configuration / activation of timeslots using OML2000 / RSL?
  • ensuring that GPRS related SI, particularly SI13 are broadcast via BCCH
  • implementation of PCU TRAU frame format and converter between osmo-pcu PHY interface and them
    • 16k sub-slot and 64k slot formats
    • associated PCU SYNC protocol
    • all various coding schemes
  • paging coordination between BSC and PCU

PDCH timeslot configuration

It seems that in OM2000 all TCH (/F, /H, PDCH) are configued with a Combination "8", and no differentiation is made

The actual activation of the channel is expected via RSL. So it's analogous to a RSL CHAN ACT for TCH/H or TCH/F, but we also do this for a PDCH. In order to do so, we send a RSL CHAN ACT with Channel Number 0b11000 + the timeslot number. Deactivation works the same way.

GPRS RACH requests

The BSC must identify the GPRS RACH requests (similar to osmo-bts currently) and pass them into the PCU. This could be done using the same pcu socket interface that already exists.

GPRS paging

Thre's a RSL "Packet Paging Indication IE" (IEI = 0xF3) that the BSC can include when sending a paging request to the BTS. It's currently not clear what this is used for and why it is required.

TRAU frames

Classic GSM TRAU frames (for circuit switched voice) are transmitted on 16kBps sub-slots and are 39 octets (312 bits) long. They thus occur every 19.5ms. Four 16kbps sub-slots are multiplexed into a 64kbps E1 slots. For more information see 3GPP TS 48.060.

Ericsson also introduces 64kbps TRAU frames (for higher EGPRS coding schemes).

The Synchronization of TRAU frames is based on a 16-bit all-zero field at the beginning of each TRAU frame (called the T0 bits) followed by a signle 1 bit (called the T1 bit).

16kBps sub-slots

PCU-DATA.ind

This frame can be used by a CS-1 or CS-2 frame transmitted by the PCU, i.e. downlink.

T 17 T0*16,T1*1 Sync Word
C 8 C1..C8 Control Bits (Frame Type, Time adjustmentValue,Uplink Frame Error)
PC 1 PC Parity (C1..C8)
E 16 E1..E16 Codec Control, Uplink Channel Mode, Power Control
PE 1 PE Parity (E1..E16)
D 273 D1..D273 Data bits
TA 4 TA1..TA4 Time Alignment

CCU-DATA.ind

This frame can be used by a CS-1 or CS-2 frame transmitted by the CCU, i.e. uplink.

64kBps slots

PCU-DATA-64.ind

T 65 T0*64,T1*1 Sync Word
D 48 D1..D48 Data bits
C 8 C1..C8 Control Bits
PC 1 PC Parity (C1..C8)
E 36 E1..E36
PE 1 Parity (E1..E36)
S 21 S1..S21
D 1132 D1..D1132 Data bits
TA 16 TA1..TA16 Time Alignment bits
Total 1328

PCU-DATA-MCS9.ind

T 17 T0*16,T1*1 Sync Word
D 48 D1..D48 Data bits
C 8 C1..C8 Control Bits
PC 1 PC Parity (C1..C8)
E 9 E1..E9
PE 1 Parity (E1..E36)
D 1172 D49..D1228 Data bits
TA 16 TA1..TA16 Time Alignment bits
Total 1272

CCU-DATA-64.ind

T 65 T0*64,T1*1 Sync Word
C 7 C1..C7 Control bits (FT, TAV)
PC 1 PC Parity (C1..C7)
E 57 E1..E57 DBE, Codec Status, Receiver Level, Access Delay Deviation, Block Quality Measurement, Block Status Report, Spare, MEAN_BEP, CV_BEP, Header Quality, Data Block Quality
PE 1 PE Parity (E1..E57)
S 3 S1..S3 Spare (set to 1)
D 1138 D1..D1138 Data bits
TA 8 TA1..TA8 Time Alignment bits
Total 1280

CCU-DATA-MCS9.ind

T 17 T0*16,T1*1 Sync Word
D 48 D1..D48 Data bits
C 7 C1..C7 Control bits
PC 1 PC Parity (C1..C7)
E 23 E1..E23
PE 1 PE Parity (E1..E23)
S 2 Spare
D 1165 D49..D1221 Data bits
TA 8 Time Alignment bits
Total 1272

CCU-SYNC-64.ind

Sent from CCU to PCU (uplink)

T 17 T0*16+T1*1 Sync Word
C 8 C1..C8 Control bits (FT, TAV, DFE)
PC 1 PC Parity (C1..C8)
E 1 E1 DBE (DownlinkBlockError)
PE 1 PE Parity (E1)
D 44 D1..D44 Data bits
T 1 T1
D 55 D45..D99 Data bits
T 1 T1
D 1079 D100..D1178 Data bits (DPSEQ, DaFNu, DaFNd)
TA 8 TA1..TA8 Time Alignment bits
Total 1216

PCU-SYNC-64.ind

T 65 T0*64+T1*1 Sync Word
C 8 C1..C8 Control
PC 1 Parity (C1..C8)
D 54 D1..D53 Data bits
T 1 T1
D 63 Data bits
T 1 T1
D 1071 .D1172 Data bits
TA 16 TA1..TA16 Time Alignment bits
Total 1280
Files (1)
e1_egprs_testnetwork.tar e1_egprs_testnetwork.tar 30 KB dexter, 04/04/2023 10:00 AM

Updated by laforge over 7 years ago · 4 revisions