= CTU Console =

The CTU each have a DB-9 serial port with a RS-232 UART on them.

There is a text based command line interface available. However, the command set seems pretty limited

Boot up
During boot, there are no log messages. Only after boot has completed, the following information
is printed: {{{
EQCP TTY Operational Code
Motorola Confidential Proprietary 1997-8
Developed by Charlie Green and Lonnie Donovan Version/Revision : 050B.0400
Release Date : Jan 13 2005 Last Reset was a Hard Reset

EQCP >
}}}

Commands === help === {{{
EQCP > help
BASIC LEVEL ACCESS COMMANDS ===========================
ALARMS CALCHK CHKSUM HELP ?
HWVER LOGOUT PS STAT SN QRY STATE
SWVER
}}}

=== alarms === {{{
EQCP > alarms
EQCP >

Incorrect State For Command

}}}

=== calchk === {{{
EQCP > calchk
EQCP >

RX Branch 1:  CAL  CHECKSUM   RX Branch 2:  CAL  CHECKSUM
AIC YES fff6 AIC YES fffe
AGC YES d25d AGC YES ce69
BAY YES 720f BAY YES 6e43
BBG YES 0027 (This is for both branches.)
DCO YES 8811 DCO YES 5dd7
FREQ YES ff59 FREQ YES fd78
IFG YES 0006 IFG YES 0006
RSSI YES a1e8 RSSI YES 99f2
TX CAL CHECKSUM
DET YES 347e
PWR YES 05b6
TX YES 0003
VVA YES 8d83
}}}

=== chksum === {{{
EQCP > chksum
EQCP >

The Checksum Value is                     : $c0ffee
}}}

=== hwver === {{{
EQCP > hwver
EQCP >

The Radio Type is                         : Thor
The RF Hardware is configured for : DCS1800_HP
The Hardware Version is : $5
}}}

=== swver === {{{
EQCP > swver
EQCP >

The Software Version is            : $50b
The Software Revision is : $400
The Feature Capatibility Bitmap is : $ 0 0 0 73
}}}

=== ps stat === {{{
EQCP > ps stat
EQCP >

Alarmed at the value outside -6V +/-5%
Alarmed at the value outside +6V +/-5%
Alarmed at the value under 20V
Alarmed at the value over 30V
Alarmed at the value under 12V -20%
Alarmed at the value over +3.3V +10%
Alarmed at the value outside +5V +/-5%
Alarmed at the value outside -5V +/-5%
}}}

=== sn qry === {{{
EQCP > sn qry
EQCP >

Radio Serial Number : X77F0P1APT
Radio Kit Number : SWRG5197DA
Radio Description : THOR 1800 XCVR
Board Serial Number : X77F0P18A2
Board Kit Number : SWRG5198BBF
}}}

=== state === {{{
EQCP > state
EQCP >

INVALID processor selected
}}}