Actions
Stollmann TA+POC¶
- Table of contents
- Stollmann TA+POC
ISDN Modem/TerminalAdapter.
Multiple hardware revisions exist.
Hardware (Rev3)¶
Supply Voltage | 5V DC |
Power Consumption | ~2.1W |
RS232 Connector | DB9 |
ISDN Line Connector | RJ45 |
Pictures¶
Label:
TA+POC S/N 101322 HW: V3/8Mbit FW: 5.340 Art. No: 935-51529 Stollmann E+V GmbH
AT-Commands¶
ATI TA+POC OK OK ATI1 64 OK ATI2 OK ATI3 V5.340 OK ATI4 Stollmann E+V GmbH OK ATI5 0-DSS1 OK ATI6 (c) Copyright Stollmann E+V GmbH OK ATI7 OK ATI9 ($STO1004\1234AB89\MODEM\STO1004\TA+POC2E) OK ATI77 BOOT LOADER V1.12 201098 030E-02-00 OK ATI99 POCa000 V5.340 Feb 11 2000 16:45:28 OK
at**help cm g711law Analog encoding law conf enhanced save store parameter setting load load stored parameter set go exit configurator exit exit configurator quit exit configurator reset force hardware reset defa setup default parameter fwload load new firmware fwstart start new firmware show display actual parameter help display all commands ver display version number showall display enhanced parameter date debloc remote rmsn msn for remote access rsub subaddress for remote access rpwd password for remote access racctab display remote access table incoming calls (msn/sub) racctab1 racctab2 racctab3 racctab4 racctab5 trc trcdln length of trace buffer entry trcmsk trace mask trcon start trace trcoff stop trace trcclr clear trace buffer trcread read trace buffer trclog log trace buffer cim cmds select command interface rsttim Startup delay timer after reset rstmsg Startup message after reset dialci mode select operation mode status display status of serial and ISDN interface acctab display access table incoming calls (msn/sub) typ isdn D channel protocol ptp point to point mode s0led BRI activation mode ringtimer ring interval (100ms) rmmsg indicate remote connection txfwd data forwarding timer (t=x*50ms) acctab1 allow incoming call no/sub acctab2 allow incoming call no/sub acctab3 allow incoming call no/sub acctab4 allow incoming call no/sub acctab5 allow incoming call no/sub xtab display xtab table (xxx) xtab1 set X.25 addr, isdnno xtab2 set X.25 addr, isdnno xtab3 set X.25 addr, isdnno xtab4 set X.25 addr, isdnno xtab5 set X.25 addr, isdnno catab display hotline table (msn/sub) catab1 catab2 catab3 atparam ats2 ats3 ats4 ats5 ats6 ats7 ats91 atopt atrcs atrej s10 send3p x3param p001 p002 p003 p004 p005 p006 p007 p008 p009 p010 p011 p012 p013 p014 p015 p016 p017 p018 p019 p020 p021 p022 dial cau last cause of data call msn msn = isdnno./subaddr sub llc llc incoming and outgoing hlc hlc incoming and outgoing bc bc incoming and outgoing prot B channel protocol cha charging information chatol accumulated charging information ats0 AT: rings to answer brn network baudrate bsize frame length, valid range 16...2048 br serial baudrate dbits databits (7,8) sbits stopbits (1,2) prty parity cdtr DTR control cdcd DCD control ccts CTS control cdsr DSR control flc flow control idle data timeout for disconnect cmlp control multilink PPP chappwd CHAP password v25bisout enable/disable connect message from V.25bis v110llc send V110 LLC v110flc enable disable V110 flow control npl ISDN Numbering Plan bod bandwidth on demand bodiv bod increase value bodit bod increase time boddv bod decrease value boddt bod decrease time tdi timer delay incoming cmds2 Subcommandset OK at**mode? select operation mode 0 - AT-V.110 1 - V.25bis-V.110 2 - X.3-X.25 B 3 - X.3-X.31 D OK at**status Current status information TA+POC serial line: DTR:on, RTS:on, DSR:on, CTS:on, DCD:off, RI:off ISDN: L1:up Dch: Prot:DSS1 State:disconnected, CdPN:, CgPN:, prev error: 0 Bch: Prot:V.110 State:disconnected, CdPN:, CgPN: OK at**isdn 0-DSS1 OK at**isdn? D channel protocol 0 - DSS1 1 - 1TR6 OK at**show cm g711law: 0-Automatic remote rmsn: * rsub: * rpwd: trc trcdln: 256 trcmsk: 0000000300020500 cim cmds: 0-ATcmd dialci isdn: 0-DSS1 ptp: 0-P-MP dial msn: * sub: * prot: 0-V.110 cha: 1 chatol: 2737 brn: 0-adaptive bsize: 2048 br: 0-adaptive dbits: 8 sbits: 1 prty: 0-none cdtr: 2-control cdcd: 1-connected ccts: 1-on cdsr: 0-on flc: 3-RTS/CTS idle: 0 cmlp: 0 chappwd: v25bisout: 0 v110llc: 1 v110flc: 1 npl: 80 bod: 0 bodiv: 40 bodit: 30 boddv: 40 boddt: 30 tdi: 0 cmds2: 0 OK at**showall cm g711law: 0-Automatic remote rmsn: * rsub: * rpwd: racctab1: racctab2: racctab3: racctab4: racctab5: trc trcdln: 256 trcmsk: 0000000300020500 cim cmds: 0-ATcmd rsttim: 40 rstmsg: 0 dialci isdn: 0-DSS1 ptp: 0-P-MP s0led: 1 ringtimer: 50 rmmsg: 0 txfwd: 1 acctab1: acctab2: acctab3: acctab4: acctab5: xtab1: xtab2: xtab3: xtab4: xtab5: catab1: catab2: catab3: atparam ats2: 43 ats3: 13 ats4: 10 ats5: 8 ats6: 3 ats7: 30 ats91: 0 atopt: 25 atrcs: 4 atrej: 0 s10: 0 send3p: 1 x3param p001: 0 p002: 0 p003: 0 p004: 5 p005: 0 p006: 69 p007: 8 p008: 0 p009: 0 p010: 0 p011: 0 p012: 0 p013: 0 p014: 0 p015: 0 p016: 0 p017: 0 p018: 0 p019: 0 p020: 0 p021: 0 p022: 0 dial msn: * sub: * llc: hlc: bc: 8890 prot: 0-V.110 cha: 1 chatol: 2737 ats0: 1 brn: 0-adaptive bsize: 2048 br: 0-adaptive dbits: 8 sbits: 1 prty: 0-none cdtr: 2-control cdcd: 1-connected ccts: 1-on cdsr: 0-on flc: 3-RTS/CTS idle: 0 cmlp: 0 chappwd: v25bisout: 0 v110llc: 1 v110flc: 1 npl: 80 bod: 0 bodiv: 40 bodit: 30 boddv: 40 boddt: 30 tdi: 0 cmds2: 0 OK
Updated by roox 11 months ago · 1 revisions