05/22/2024

11:33 AM OsmoMSC Bug #6461: GSM 04.08 phase 1: Mobile terminated setup messages - octet 3a in case of speech
Related: https://gerrit.osmocom.org/c/libosmocore/+/36784 - but the encoding should consider the MS specification pha... nt2mku
10:23 AM OsmoMSC Bug #6461 (New): GSM 04.08 phase 1: Mobile terminated setup messages - octet 3a in case of speech
Some early GSM phones implementing phase 1 specification (here: Siemens P1; S/W version 18.06.93 09:58:48) reject mob... nt2mku
12:18 AM OsmoBSC Bug #6459: Siemens P1 stops uplink transmission if MS power level is being set below 15 dBm
laforge wrote in #note-10:
> I checked TS 05.05 4.23 and it already contains higher power control levels. So only ph...
nt2mku

05/21/2024

04:24 PM OsmoBSC Bug #6459: Siemens P1 stops uplink transmission if MS power level is being set below 15 dBm
...and here is another document for DCS (which contains the ETSI STY files).
nt2mku
04:10 PM OsmoBSC Bug #6459: Siemens P1 stops uplink transmission if MS power level is being set below 15 dBm
Word 6.0 for WinNT runs fine on Win10. nt2mku
01:49 PM OsmoBSC Bug #6459: Siemens P1 stops uplink transmission if MS power level is being set below 15 dBm
Thanks for moving the ticket. I did another test today generating trace files:
* PCAP of OsmoBTS-gsmtap and RSL
* Log...
nt2mku

05/20/2024

02:38 PM OsmoBSC Bug #6459: Siemens P1 stops uplink transmission if MS power level is being set below 15 dBm
Sorry, wrong project category. It's for OsmoBSC, so please either delete or move to OsmoBSC. Thanks. nt2mku
02:36 PM OsmoBSC Bug #6459 (New): Siemens P1 stops uplink transmission if MS power level is being set below 15 dBm
This is more a documentation about a speciality of the Siemens P1 (Telekom D1 314) than a bug report.
* If setting...
nt2mku

05/02/2024

09:22 PM Retronetworking Wiki edit: Nokia_EKSOS_Initial_configuration (#9)
nt2mku
09:18 PM Retronetworking Wiki edit: Nokia_EKSOS_Initial_configuration (#8)
nt2mku

Also available in: Atom