Project

General

Profile

Bug #1907

osmo-qcdiag detects CRC errors relatively often

Added by laforge 7 months ago. Updated 7 months ago.

Status:
New
Priority:
Normal
Assignee:
-
Start date:
01/11/2017
Due date:
% Done:

10%


Description

Irrespective of the baud rate used, and even without too much DIAG activity, osmo-qcdiag detects CRC errors of the DIAG frames. This is odd, particularly as the framing code is taken from the Qualcomm Linux Kernel DIAG subsystem, i.e. it is from Qualcomm themselves.

I'm not sure when that happens, but let's try to narrow this down furher by looking at the actual frames in question.

History

#1 Updated by laforge 7 months ago

  • % Done changed from 0 to 10

Interestingly, this happens a lot with EC20/EC25, but doesn't happen at all when using a Gobi2000 device. So it might be something specific (and/or broken) in Quectel EC2x?