= Troubleshooting = 

 == Known problems with the LMT connection == 

 {{{ 
 Problem: 
 'bs11_config' can't get a connection to the BS-11 (no 'LMT LOGON: ACK') 

 Solution: 
 The BS-11 is a little bit choosy about the RS232 levels, I discovered some problems  
 with my Dell PC (could receive anything, but no tx). Just switch to an el-cheapo USB 
 to Serial adapter, this should solve the problem. 

 Some background notes: 
 We measured the RS232 levels and we found out that the level of our RS232<==>USB Adaptor 
 is much lower (about +/-6 Volts) than normaly expected (+/-12V). The BS11 transmits at a 
 semeliar level (about 8 Volts). This may be an explaination why the BS11 does not like 
 the normal (+/-12V) levels. See attached files (Lmt_*) for oscilloscope screenshots. 

 Maybe a simple voltage-devider at TX on the PC side will also solve the problem... 

 












 }}} 