10/23/2020
- 09:36 AM osmo-ccid-firmware Bug #4805: The reader is mute after a T=1 data block
- I don't think that 672a96044c89243f37e73209b2e4edd72e7c9498 fixed the problem.
But the patch in ef393c31e887f548db13... - 08:50 AM osmo-ccid-firmware Bug #4815: PowerUp when no card is inserted fails after a very long delay: 60 seconds
- I upgraded the firmware to version from 22-Oct-2020, version sysmoOCTSIM 0.2.48-4c76.
The problem is now fixed. I ge...
10/17/2020
- 05:56 PM osmo-ccid-firmware Bug #4815: PowerUp when no card is inserted fails after a very long delay: 60 seconds
- Wonderful, and fast correction.
I guess it is possible to update the reader firmware. Can you provide me a documen... - 04:12 PM osmo-ccid-firmware Bug #4815: PowerUp when no card is inserted fails after a very long delay: 60 seconds
- Hoernchen wrote:
> ...That being said the timeout does appears to be a bit too long, it is usually the whole time re... - 02:44 PM osmo-ccid-firmware Bug #4805: The reader is mute after a T=1 data block
- rousseau wrote:
> I don't know if the reader is blocked. But unpluging and pluging the USB cable does not make the r... - 02:11 PM osmo-ccid-firmware Bug #4815 (Resolved): PowerUp when no card is inserted fails after a very long delay: 60 seconds
- If I insert a card connector but without a SIM card in the card connector then the reader (sysmoOCTSIM in my case) re...
10/14/2020
- 03:39 PM osmo-ccid-firmware Bug #4805: The reader is mute after a T=1 data block
- laforge wrote:
> b) why does the hardware watchdog not reset the device
What is the watchdog timer value?
Maybe ... - 03:21 PM osmo-ccid-firmware Feature #4806: Add support of T=1?
- laforge wrote:
> > The reader works in TPDU mode so a lot of the T=1 work is done by the CCID driver on the host.
>... - 09:26 AM osmo-ccid-firmware Feature #4806 (New): Add support of T=1?
- The sysmoOCTSIM reader does support only the T=0 protocol as indicated in the USB CCID descriptor:
dwProtocols: 0x... - 09:18 AM osmo-ccid-firmware Bug #4805 (Resolved): The reader is mute after a T=1 data block
- I use the sysmoOCTSIM. The reader declares in dwProtocols the support of T=0 only.
But I am a bad guy and I try wi...