Project

General

Profile

Actions

Bug #5541

closed

CBSP: KILL COMPLETE / KILL FAILURE shouldn't contain Cell List IE

Added by laforge about 2 years ago. Updated about 2 years ago.

Status:
Resolved
Priority:
High
Assignee:
Category:
-
Target version:
-
Start date:
04/21/2022
Due date:
% Done:

100%

Spec Reference:

Description

TS 48.059 Section 8.1.3.5 / 8.1.3.6 state:

The Number of Broadcasts Completed List IE, if present, contains a list of cells for which the kill operation of the CBS message succeeded.
The Cell List IE, if present, contains the cells in which the emergency message is successfully terminated.

Right now we
  • do not support KILL for emergency at all (separate bug #5540)
  • always populate both Number of Broadcasts Completed List IE and Cell List IE for CBS messages

Related issues

Related to OsmoBSC - Bug #5540: CBS: Emergency message cannot be killedResolvedlaforge04/21/2022

Actions
Related to OsmoBSC - Bug #5539: CBSP WRITE REPLACE without Old Serial Number should result in failureResolvedlaforge04/21/2022

Actions
Actions #1

Updated by laforge about 2 years ago

  • Related to Bug #5540: CBS: Emergency message cannot be killed added
Actions #2

Updated by laforge about 2 years ago

  • Related to Bug #5539: CBSP WRITE REPLACE without Old Serial Number should result in failure added
Actions #3

Updated by laforge about 2 years ago

  • Status changed from New to In Progress

The easy way out seems to be to use the Channel Indicator IE to distinguish CBS from Emergency:

This IE is only included if the message refers to a CBS message.

Working on a related patch and tests.

Actions #4

Updated by laforge about 2 years ago

  • Status changed from In Progress to Resolved
  • % Done changed from 0 to 100

Applied in changeset commit:osmo-bsc|5c1433cafd680a0a1634a0e2e881540d8e5e1be0.