Project

General

Profile

Actions

Osmo-gbproxy VTY » History » Revision 2

« Previous | Revision 2/5 (diff) | Next »
laforge, 02/19/2016 10:48 PM
add vty reference for gbproxy


This page is a reference fo all VTY commands that you can use interactively on the osmo-gbproxy VTY telnet interface on TCP port 4246

In addition, the same commands are used for the configuration file.

configuration reference

gbproxy level

nsip sgsn remote ip A.B.C.D

Set the remote IP address for the connection to the SGSN.

nsip sgsn remote port <0-65534>

Set the remote UDP port for the connection to the SGSN.

nsip sgsn nsei <0-65534>

Set the NSEI for the connection to the SGSN.

nsip sgsn nsvci <0-65534>

Set the NS-VCI for the connection to the SGSN.

ns level

timer (tns-block|tns-block-retries|tns-reset|tns-reset-retries|tns-test|tns-alive|tns-alive-retries) <0-65535>

Set the respective NS (GSM TS 08.16) timer to the corresponding value (in seconds):
  • tns-block -- Timer between NS-BLOCK attempts without any NS-BLOCK-ACK response
  • tns-block-retries -- How often to retransmit an unacknowledged NS-BLOCK
  • tns-reset -- Timer between NS-RESET attempts without any NS-RESET-ACK response
  • tns-reset-retries -- How many times should we retry to send NS-RESET
  • tns-test -- How many seconds to wait for the response to a TEST procedure
  • tns-alive -- How many seconds to wait for an answer to the ALIVE procedure
  • tns-alive-retries -- How often should we retry the ALIVE precedure before declaring the link DEAD

nse <0-65535> nsvci <0-65534>

Configure a persistent NS-VC with a given NSEI and NSVCI

nse <0-65535> remote-ip A.B.C.D

Set the remote IP address for a persistent NS-VC

nse <0-65535> remote-port <0-65535>

Set the remote UDP port for a persistent NS-VC

nse <0-65535> remote-role (sgsn|bss)

Set whether the remote end of the specified persistent NS-VC is a BSS or SGSN.

no nse <0-65535>

Remove the persistent configuration for the specified NSE

runtime commands

show ns [stats]

Show a list of all existing NS-VCs

proxy.osmocom.org> show ns
NSEI  2342, NS-VC  2342, Remote: BSS ,  DEAD   BLOCKED,  192.161.252.121:23000
NSEI  8989, NS-VC  8989, Remote: SGSN, ALIVE UNBLOCKED,    192.181.57.10:23000

If the stats parameter is given, statistics will be included.

show ns (nsei|nsvc) <0-65535> [stats]

Show information for one specific NS-VC identified by NSVCI or NSEI, optionally including stats

proxy.osmocom.org> show ns nsei 2342 stats
NSEI  2342, NS-VC  2342, Remote: BSS ,  DEAD   BLOCKED,  192.161.252.121:23000
 NSVC Peer Statistics:
  Packets at NS Level ( In):      402 (0/s 0/m 0/h 402/d)
  Packets at NS Level (Out):      253 (0/s 0/m 0/h 253/d)
  Bytes at NS Level   ( In):     3787 (0/s 0/m 0/h 3787/d)
  Bytes at NS Level   (Out):      269 (0/s 0/m 0/h 269/d)
  NS-VC Block count        :        1 (0/s 0/m 0/h 1/d)
  NS-VC gone dead count    :        1 (0/s 0/m 0/h 1/d)

logging filter nsvc (nsei|nsvci) <0-65535>

Set a logging filter, i.e. only display log messages related to the specified NSEI / NSVCI

Files (0)

Updated by laforge about 8 years ago · 2 revisions

Add picture from clipboard (Maximum size: 48.8 MB)