BS11Configuration » History » Version 1
laforge, 02/19/2016 10:47 PM
1 | 1 | laforge | == Configuration of BTSM Object == |
---|---|---|---|
2 | |||
3 | * BS11 requires PCM30CRC4 64kBit/s no Subslots |
||
4 | * OM Layer on Timeslot 1 |
||
5 | * TEI for OM Layer default Siemens is 25 (but configurable in BS11 [wiki:LMT]) |
||
6 | |||
7 | * the following parameters are not configurable |
||
8 | * RSL Layer on Timeslot 1, too |
||
9 | * TEI for RSL is fixed in Siemens equipment |
||
10 | * TEI = 0 für TRX0 |
||
11 | * TEI = 1 für TRX1 |
||
12 | * Attention: if you select OM Layer TEI 0 oder 1, RSL can no longer be brought up |
||
13 | |||
14 | * Timeslots for TCHs |
||
15 | * TRX0: TS2 und TS3 |
||
16 | * TRX1: TS4 und TS5 |
||
17 | |||
18 | == E1 interface == |
||
19 | LI Objekt: Line MULTIDROP |
||
20 | Impedance 120 Ohm balanced to connect to HFC-E1 board |
||
21 | Additionally you will need to change some jumpers on the connector board |
||
22 | of BS11 (FIXME: which ones?) |
||
23 | |||
24 | == Database == |
||
25 | Important database settings: |
||
26 | |||
27 | * the database has to be downloaded from PC via E1 to BS11 |
||
28 | |||
29 | |||
30 | * BCCH channel combination Type 5 oder 8 (including SDCCH for SMS) |
||
31 | * TCH combination 0 oder 9 |
||
32 | {{{ |
||
33 | Cell config: Not hopping |
||
34 | No Concentric Cell = 0 |
||
35 | Radiomeasgran =254 |
||
36 | No Power Reduction = 0 |
||