Project

General

Profile

Bug #3166

OsmoMSC permits ESME configuration with password length > 8

Added by laforge over 1 year ago. Updated 23 days ago.

Status:
Resolved
Priority:
Low
Assignee:
Category:
SMPP Interface
Target version:
-
Start date:
04/14/2018
Due date:
% Done:

100%

Resolution:

Description

The SMPP 3.4 specification defines the password field as a "Variable-length octet string with maximum length of 9", and according to table 3-1 this means including the terminating NUL-byte.

However, OsmoMSC allows to configure longer passwords in the ESME configuration. Those passwords will then never match, as libsmpp34 performs length validation and generates a parser error for anyone trying to send a longer password via SMPP.

History

#1 Updated by laforge 2 months ago

  • Status changed from New to In Progress
  • Assignee changed from sysmocom to laforge
  • % Done changed from 0 to 80

#2 Updated by laforge 23 days ago

  • Status changed from In Progress to Resolved
  • % Done changed from 80 to 100

patch was already merged on May 10

Also available in: Atom PDF