bs11_config is a small commandline program that can be used to configure the [wiki:BS-11] BTS using its RS232 link.
It can perform a subset of the functions that are typically performed using the Siemens LMT (Local Maintenance Terminal) software, such as * querying some essential configuration values * creating and deleting TRX1 objects * download of SAFETY LOAD software * download of BTS software * creating an initial configuration (such as creating BBSIG,CCLK,PA,... objects) * setting the Tx output power of the RF amplifier
Reference=== Querying the BS-11 ===
{{{
$ ./bs11_config -p /dev/ttyUSB0 query
bs11_config (C) 2009 by Harald Welte and Dieter Spaar
This is FREE SOFTWARE with ABSOLUTELY NO WARRANTY
LMT LOGON: ACK
PHASE: 3 Normal MBCCU0: Load MBCCU1: Load Abis-link: Restoring
BS11 ATTRIBUTES:
BS-11 ESN PCB Serial Number: 001107
BS-11 ESN Hardware Code Number: 135-2044/03.07
BS-11 ESN Firmware Code Number: 135-2044/03.07
SITE MANAGER ATTRIBUTES:
E1 Channel: Port=0 Timeslot=1 (Full Slot)
TEI: 25
BS11 Power Amplifier 0 ATTRIBUTES:
TRX Power: 30mW (GSM)
BS11 Power Amplifier 1 ATTRIBUTES:
TRX Power: 30mW (GSM)
}}}
=== Disconnect ===
This puts the BTS out of Normal mode into Maintenance mode and disconnects it from the BSC
{{{
$ ./bs11_config -p /dev/ttyUSB0 disconnect
bs11_config (C) 2009 by Harald Welte and Dieter Spaar
This is FREE SOFTWARE with ABSOLUTELY NO WARRANTY
LMT LOGON: ACK
PHASE: 3 Normal MBCCU0: Load MBCCU1: Load Abis-link: Restoring
PHASE: 2 Maintenance MBCCU0: Load MBCCU1: Load Abis-link: Down
}}}
=== Reconnect ===
This puts the BTS out of Maintenance mode into Normal mode and reconnects it to the BSC
{{{
$ ./bs11_config -p /dev/ttyUSB0 reconnect
bs11_config (C) 2009 by Harald Welte and Dieter Spaar
This is FREE SOFTWARE with ABSOLUTELY NO WARRANTY
LMT LOGON: ACK
PHASE: 2 Maintenance MBCCU0: Load MBCCU1: Load Abis-link: Down
PHASE: 3 Normal MBCCU0: Load MBCCU1: Load Abis-link: Restoring
}}}
=== Download SMU Safety Load ===
{{{
$ ./bs11_config -p /dev/ttyUSB0 -S /path/to/my/BTSBMC76.SWI
}}}
'''NOTE: The OpenBSC/bs11-abis project is not providing any Firmware images for the BS-11, as they are copyrighted material'''
=== Minimal Configuration ===
The minimal configuration is automatically created if the BS-11 enters the ''MINIMAL CONFIG REQUIRED'' state after the SMU safety load is installed.
=== Download Software Load ===
{{{
$ ./bs11_config -p /dev/ttyUSB0 -s /path/to/my/HS011106.SWL
}}}
If the BS-11 is not in Maintenance State, it first needs to be detached from the BSC (using -D option)
{{{
$ ./bs11_config -p /dev/ttyUSB0 -D -s /path/to/my/HS011106.SWL
}}}
If you want to force a download, just add the ''-f'' parameter.
'''NOTE: OpenBSC is not providing any Firmware images for the BS-11'''
=== Observing BS-11 boot process ===
This is the output of bs11_config while observing the boot process. You will see every line
many times, as the status is refreshed every five seconds.
{{{
$./bs11_config -p /dev/ttyUSB0
bs11_config (C) 2009 by Harald Welte and Dieter Spaar
This is FREE SOFTWARE with ABSOLUTELY NO WARRANTY
LMT LOGON: ACK
T-Link: Down Abis-link: Down MBCCU0: No Load MBCCU1: No Load PHASE: 1 SUBPHASE: Warm Up...
T-Link: Down Abis-link: Down MBCCU0: No Load MBCCU1: No Load PHASE: 1 SUBPHASE: Load SMU Intended...
T-Link: Down Abis-link: Down MBCCU0: No Load MBCCU1: No Load PHASE: 2 SUBPHASE: Load MBCCU...
T-Link: Down Abis-link: Down MBCCU0: No Load MBCCU1: Load BTSCAC PHASE: 2 SUBPHASE: Load MBCCU...
T-Link: Down Abis-link: Down MBCCU0: Load BTSCAC MBCCU1: Load BTSCAC PHASE: 2 SUBPHASE: Load MBCCU...
T-Link: Down Abis-link: Down MBCCU0: Load BTSCAC MBCCU1: Load BTSDRX PHASE: 2 SUBPHASE: Load MBCCU...
T-Link: Down Abis-link: Down MBCCU0: Load BTSDRX MBCCU1: Load BTSDRX PHASE: 2 SUBPHASE: Load MBCCU...
T-Link: Down Abis-link: Down MBCCU0: Load BTSDRX MBCCU1: Load BTSBBX PHASE: 2 SUBPHASE: Load MBCCU...
T-Link: Down Abis-link: Down MBCCU0: Load BTSBBX MBCCU1: Load BTSBBX PHASE: 2 SUBPHASE: Load MBCCU...
T-Link: Down Abis-link: Down MBCCU0: Load BTSBBX MBCCU1: Load BTSARC PHASE: 2 SUBPHASE: Load MBCCU...
T-Link: Down Abis-link: Down MBCCU0: Load BTSARC MBCCU1: Load BTSARC PHASE: 2 SUBPHASE: Load MBCCU...
T-Link: Down Abis-link: Down MBCCU0: Load BTSARC MBCCU1: Load PHASE: 2 SUBPHASE: Load MBCCU...
T-Link: Down Abis-link: Down MBCCU0: Load MBCCU1: Load PHASE: 2 SUBPHASE: Load MBCCU...
T-Link: Down Abis-link: Restoring MBCCU0: Load MBCCU1: Load PHASE: 3 SUBPHASE: Normal...
T-Link: Down Abis-link: Up MBCCU0: Load MBCCU1: Load PHASE: 3 SUBPHASE: Normal...
}}}
Updated by laforge about 8 years ago · 5 revisions