Actions
Bug #2367
closedOpenBSC doesn't send staically configured system information
Start date:
07/15/2017
Due date:
% Done:
100%
Resolution:
Spec Reference:
Description
When configuring system information in "static" mode (i.e. manual hex-dumps of SI messages), then those are not sent to the BTS.
Updated by laforge almost 7 years ago
- Status changed from New to In Progress
- % Done changed from 0 to 20
The reason appears to be that we set "bts->si_valid = 0" since 8b1a2f8cd7a81c6b8c7cdb0963dcf89de7c46100 :(
Instead, we have to initialize bts->si_valid to bts->si_mode_static, i.e. start with those that are static and not to be auto-generated.
Found while developing http://git.osmocom.org/osmo-ttcn3-hacks/tree/sysinfo
Updated by laforge almost 7 years ago
- % Done changed from 20 to 80
Updated by laforge almost 7 years ago
- Status changed from In Progress to Closed
- % Done changed from 80 to 100
Actions