Actions
Bug #4614
open"bogus channel load sample" when using BS-11, Nokia or Ericsson BTS
Start date:
06/15/2020
Due date:
% Done:
30%
Spec Reference:
Description
Mon Jun 15 15:36:12 2020 DRLL chan_alloc.c:208 (bts=0) bogus channel load sample (used=0 / total=0) Mon Jun 15 15:36:13 2020 DRLL chan_alloc.c:208 (bts=0) bogus channel load sample (used=0 / total=0)
Also, interestingly:
OsmoBSC> show trx TRX 0 of BTS 0 is on ARFCN 121 Description: (null) RF Nominal Power: 24 dBm, reduced by 0 dB, resulting BS power: 24 dBm NM State: Oper 'NULL', Admin 'Unlocked', Avail 'Power off' RSL State: connected Baseband Transceiver NM State: Oper 'NULL', Admin 'unknown 0x0', Avail 'Power off' E1 Signalling Link: E1 Line 2, Type dahdi: Timeslot 1, Mode RSL E1 TEI 1, SAPI 0
I think the problem is that the Siemens BS-11 MO structure is quite unlike what TS 12.21 describes, so the baseband transceiver object is simply never initialized.
The " OC=SIEMENSHW INST=(03,00,00)" might be can idea?
Actions