open

"bogus channel load sample" when using BS-11, Nokia or Ericsson BTS

Added by laforge almost 4 years ago. Updated about 3 years ago.

Status:
Stalled
Priority:
Low
Assignee:
Category:
Ericsson BTS
Target version:
-
Start date:
06/15/2020
Due date:
% Done:

30%

Spec Reference:

Description

Mon Jun 15 15:36:12 2020 DRLL chan_alloc.c:208 (bts=0) bogus channel load sample (used=0 / total=0)
Mon Jun 15 15:36:13 2020 DRLL chan_alloc.c:208 (bts=0) bogus channel load sample (used=0 / total=0)

Also, interestingly:

OsmoBSC> show trx
TRX 0 of BTS 0 is on ARFCN 121
Description: (null)
  RF Nominal Power: 24 dBm, reduced by 0 dB, resulting BS power: 24 dBm
  NM State: Oper 'NULL', Admin 'Unlocked', Avail 'Power off'
  RSL State: connected
  Baseband Transceiver NM State: Oper 'NULL', Admin 'unknown 0x0', Avail 'Power off'
  E1 Signalling Link:
    E1 Line 2, Type dahdi: Timeslot 1, Mode RSL
    E1 TEI 1, SAPI 0

I think the problem is that the Siemens BS-11 MO structure is quite unlike what TS 12.21 describes, so the baseband transceiver object is simply never initialized.

The " OC=SIEMENSHW INST=(03,00,00)" might be can idea?