open

hnbgw fails to connect to the sgsn

Added by lynxis over 2 years ago. Updated over 2 years ago.

Status:
In Progress
Priority:
Normal
Assignee:
Target version:
-
Start date:
09/07/2021
Due date:
% Done:

0%

Spec Reference:

Description

On the event gsm setup I've noticed that sometimes the packets doesn't flow between the daemons even all are up.
I would guess it's a stale connection or a wrong routing.

It's a full setup with osmo-bsc/msc/sgsn/hnbgw (+ the other non stp services).
I restart a daemon and the data doesn't flow even the daemon is reconnecting.

My current failure is with a nano3g <> hnbgw <> stp <> sgsn.
While the CS path to the msc works.

The UE is sending a GPRS-ATTACH-REQ which correlates to the following osmo-hnbgw failure message:

Sep 07 17:48:57 rc3-gsm osmo-hnbgw[9345]: 20210907174857511 DLSCCP ERROR Received unknown conn-id 1002 for primitive N-DATA.request (sccp_scoc.c:1758)
[...] for every Attach Request 1

I've noticed this bug from time to time while working with the event setup. I could image a bug in the sccp or stp.


Files

bug_2021_09_07.tar.gz bug_2021_09_07.tar.gz 5.26 KB hnbgw,sgsn,stp logs lynxis, 09/07/2021 04:07 PM