Project

General

Profile

Bug #1584

LLC-PDU transfer from old to new PCU in case of Inter-PCU mobility missing

Added by laforge almost 2 years ago. Updated over 1 year ago.

Status:
Rejected
Priority:
High
Assignee:
Category:
-
Target version:
-
Start date:
02/23/2016
Due date:
% Done:

0%

Spec Reference:

Description

If a MS moves from one PCU to another PCU, there is an optional procedure to retrieve those LLC PDUs stored int he old PCU and forward them to the new PCU in order to avoid having to rely on higher-layer re-transmissions.

History

#2 Updated by laforge over 1 year ago

  • Assignee set to neels

#3 Updated by laforge over 1 year ago

  • Priority changed from Normal to High

#4 Updated by neels over 1 year ago

My awareness level of this issue so far is very low.

#5 Updated by laforge over 1 year ago

  • Assignee deleted (neels)

#6 Updated by laforge over 1 year ago

  • Assignee set to dexter

#7 Updated by laforge over 1 year ago

  • Assignee changed from dexter to laforge

#8 Updated by laforge over 1 year ago

  • Status changed from New to Rejected

Actually, this is only happening between SGSNs when a MS transfers from one SGSN to another SGSN, but not on the Gb interface from one PCU to another PCU.