Bug #4715
closedon CBSP RESET, osmo-bsc should terminate all CBSP PN broadcast immediately on indicated cells
Start date:
08/17/2020
Due date:
% Done:
100%
Spec Reference:
Description
So far a CBSP RESET sent to osmo-bsc fails to clear pending timers to terminate PN broadcast.
The PN broadcast is terminated (by a zero payload message) 5 seconds after a PN broadcast was instructed.
Instead, all cells indicated by the RESET should immediately stop PN broadcast,
i.e. immediately send zero-payload write commands to all affected cells,
and immediately clear all pending timers.
Also clarify whether there is other state in osmo-bsc that should be cleared on RESET but isn't.
Patches for PN broadcast are already on their way:
https://gerrit.osmocom.org/c/osmo-bsc/+/19632
https://gerrit.osmocom.org/c/osmo-ttcn3-hacks/+/19636
Updated by neels over 3 years ago
- Status changed from In Progress to Resolved
- % Done changed from 0 to 100
patches merged