closed

Feature #2724: Improve default timers

RF channel teradown timers (T3109) way too large

Added by laforge over 6 years ago. Updated about 6 years ago.

Status:
Closed
Priority:
Normal
Assignee:
Category:
-
Target version:
-
Start date:
12/10/2017
Due date:
% Done:

100%

Spec Reference:

Description

When the BSC wants to tear down a logical channel, it
  1. sends a RR CHANnel RELease to the MS via the LAPDm link (RLL on Abis)
  2. deactivates the SACCH locally on the BSS side
  3. waits for 20s, and only then issues a RF CHANnel RELease on RSL which deactivates the channel

This means that a MS that is not responding to the RR CHAN REL (because it is out of range, was switched off, is broken, has lost radio signal) causes us to use the scarce radio channel for 20s more than needed.

According to 3GP TS 44.018 Section 3.4.13, this is timer T3109 (between RR CHAN REL and RF CHAN REL). It is set to 19 seconds in our default, which is ridiculously long.

There's also T3111 which should be started when the main signalling link is disconnected.


Related issues

Related to OsmoBSC - Bug #1610: RF channel release skipping T3109Resolvedneels02/23/2016

Actions
Actions

Also available in: Atom PDF