Project

General

Profile

Actions

Feature #3483

open

handover decision: if rxlev is ok but rxqual is bad, move from TCH/H to TCH/F

Added by neels over 5 years ago. Updated over 5 years ago.

Status:
New
Priority:
Normal
Assignee:
Category:
Handover
Target version:
-
Start date:
08/20/2018
Due date:
% Done:

0%

Spec Reference:

Description

Bad quality scenario: rxlev is ok, but rxqual drops below the min_rxqual threshold.

Handover decision 2 contains a switch from TCH/H to TCH/F to improve rxqual. See on_measurement_report() in handover_decision_2.c, by the comment "Bad Quality".
However, that condition seems buggy: "if (... av_rxqual > ho_get_hodec2_min_rxqual(bts->ho))" should probably be the flipped?

To test for this with real equipment, we could manipulate the min_rxqual threshold during a call.
In ttcn3, we could use measurement reports.


Related issues

Related to OsmoBSC - Feature #1608: various handover improvements, meta-issueRejectedneels02/23/2016

Actions
Actions

Also available in: Atom PDF

Add picture from clipboard (Maximum size: 48.8 MB)