Actions
Bug #3799
closedOsmoBSC send OML "Get Attributes" with wrong length value
Start date:
02/12/2019
Due date:
% Done:
70%
Spec Reference:
Description
When sending the OML "GET ATTRIBUTES" message to the "Baseband Transceiver", OsmoBSC is sending a wrong "length" field of the OML message. See attached pcap file.
80 80 00 07 81 04 00 00 ff 1a 00 02 1c 41 ^ ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ | 10 bytes following length octet stating len=7
Files
Related issues
Updated by laforge about 5 years ago
- Status changed from New to In Progress
- % Done changed from 0 to 10
will be working on a patch. The problem is that we have tons of old OsmoBSC versions around that do this wrong. This probably was wrong already in Change-Id I2b61131b9930afd03357c0b66947ee856d58cc46 merged in May 2017 - or possibly even longer than that...
Updated by laforge about 5 years ago
- Related to Bug #1614: better identification of BTS model / capabilities to BSC added
Updated by laforge about 5 years ago
- % Done changed from 10 to 70
A fix for OsmoBSC has been submitted as https://gerrit.osmocom.org/#/c/osmo-bsc/+/12890
A work-around for OsmoBTS has been submitted at https://gerrit.osmocom.org/#/c/osmo-bts/+/12891
Updated by laforge almost 5 years ago
- Status changed from In Progress to Resolved
both patches merged quite some time ago.
Actions