Project

General

Profile

Actions

Bug #3799

closed

OsmoBSC send OML "Get Attributes" with wrong length value

Added by laforge about 5 years ago. Updated almost 5 years ago.

Status:
Resolved
Priority:
High
Assignee:
Category:
A-bis OML
Target version:
-
Start date:
02/12/2019
Due date:
% Done:

70%

Spec Reference:

Description

When sending the OML "GET ATTRIBUTES" message to the "Baseband Transceiver", OsmoBSC is sending a wrong "length" field of the OML message. See attached pcap file.

80 80 00 07 81 04 00 00 ff 1a 00 02 1c 41
         ^  ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
         |  10 bytes following   
         length octet stating len=7

Files

20190212-oml-get_attr.pcap 20190212-oml-get_attr.pcap 123 Bytes laforge, 02/12/2019 06:32 PM