The RX + TX transfers have headers which are intended to be used for a variety of bits like
- CRC error reporting
- LOS (loss of signal)
- FER (far end error)
Related issues
Updated by laforge almost 4 years ago
- Related to Bug #4750: populate new osmo-e1-hardware.git with gateware + firmware added
Updated by laforge over 3 years ago
- Status changed from New to In Progress
20:51 < tnt> LaF0rge: yeah, an interrupt endpoint for async status like LOS/ALARM/... might make more sense and just keep the header for CRC errors.
Updated by laforge over 3 years ago
- % Done changed from 0 to 70
- error reporting now implemented via interrupt EP: https://gerrit.osmocom.org/c/osmo-e1-hardware/+/21777
- Rx transfer header now only used for E1 frame number: https://gerrit.osmocom.org/c/osmo-e1-hardware/+/21717
Updated by laforge over 3 years ago
- Status changed from In Progress to Resolved
- % Done changed from 70 to 100