1 4 laforge
h1. Auerswald COMmander Basic2
2 1 laforge
3 5 laforge
{{child_pages}}
4
5
6 1 laforge
@laforge bought an "Auerswald COMmander Basic 2" PBX for purposes of building a small ISDN/PSTN network.
7
8
It currently has the following cards installed:
9
1x E1 port (for connection to e.g. a E1 RAS server)
10 2 laforge
8x S0 ports (for ISDN cards, each S0 port can host two 64k dialup)
11 1 laforge
16x a/b ports (for analog modems)
12 5 laforge
8x Up0 ports (internal 2-wire interface, not directly usable without converters back to S0)
13 2 laforge
14
h2. Web configuration interface
15
16
The configuration interface of the PBX can be reached at http://192.168.0.24 via the built-in Ethernet port (just use any static IP address in the subnet 192.168.0.0/24 for the PC/browser side).  Username "admin", Password "123456".
17
18 7 manawyrm
Bug in old firmware versions: If the web interface looks empty/only the logo is visible, the firmware needs to be updated. This (unfortunately) only seems to work in Internet Explorer. Firefox, Chrome, Edge are all not working. Version 4.2P no longer has this bug.
19 6 manawyrm
20 8 manawyrm
Problem: Only a single connection can be established to a single phone number, multichannel video calls or data transmissions are immediately disconnected
21
Fix: Ensure the device type on the subscriber settings is set to "ISDN PC-card", even if it's a telephone or similar device. 
22
23 2 laforge
h2. Dialing Plan
24
25
The telephone numbers are configured as four-digit numbers with the following keys:
26
* first digit is always '2' (other digits reserved for future extension with other PBX)
27
* second digit indicates daughterboard/module: (1-4)
28
* third digit indicates port within module (1-8)
29
* last digit is zero (analog) or 1-2 in case of BRI ports (for the two slots)
30
31
So a number like *2452* would mean:
32
* module number 4
33
* port 5 within that module (S0 bus)
34
* second 64k timeslot / participant on that bus
35
36
h2. Connections to 1U RJ45 panel
37
38
The PBX is wired to the 50-port RJ45 panel in the bottom 1U of the 6U enclosure
39
40
|_.RJ45|_.Type|_.Module|_.Port|_.Phone Number(s)|
41
|01|a/b|D|1|2110|
42
|02|a/b|D|2|2120|
43
|03|a/b|D|3|2130|
44
|04|a/b|D|4|2140|
45
|05|a/b|D|5|2150|
46
|06|a/b|D|6|2160|
47
|07|a/b|D|7|2170|
48
|08|a/b|D|8|2180|
49
|09|-|-|-|-|
50
|10|-|-|-|-|
51
|11|S0|B|1|2211, 2212|
52
|12|S0|B|2|2221, 2222|
53
|13|S0|B|3|2231, 2232|
54
|14|S0|B|4|2241, 2242|
55
|15|S0|B|5|2251, 2252|
56
|16|S0|B|6|2261, 2262|
57
|17|S0|B|7|2271, 2272|
58
|18|S0|B|8|2281, 2282|
59
|19|-|-|-|-|
60
|20|-|-|-|-|
61
|21|a/b|D|1|2310|
62
|22|a/b|D|2|2320|
63
|23|a/b|D|3|2330|
64
|24|a/b|D|4|2340|
65
|25|a/b|D|5|2350|
66
|26|a/b|D|6|2360|
67
|27|a/b|D|7|2370|
68
|28|a/b|D|8|2380|
69
|29|-|-|-|-|
70
|30|-|-|-|-|
71
|31|Up0|A|1|2411, 2412|
72
|31|Up0|A|1|2421, 2422|
73
|31|Up0|A|1|2431, 2432|
74
|31|Up0|A|1|2441, 2442|
75
|31|Up0|A|1|2451, 2452|
76
|31|Up0|A|1|2461, 2462|
77
|31|Up0|A|1|2471, 2472|
78
|31|Up0|A|1|2481, 2482|
79
|39|-|-|-|-|
80
|40|-|-|-|-|
81
|41|-|-|-|-|
82
|42|-|-|-|-|
83
|43|-|-|-|-|
84
|44|-|-|-|-|
85
|45|-|-|-|-|
86
|46|-|-|-|-|
87
|47|-|-|-|-|
88
|48|-|-|-|-|
89
|49|-|-|-|-|
90
|50|-|-|-|-|
91 3 laforge
92
93
h2. Documentation
94
95
* attachment:Auerswald_COMmander_Anleitung_fuer_Treiberinstallation_CAPI_TAPI.pdf
96
* attachment:Auerswald_COMmander_Anleitung_fuer_Treiberinstallation_CAPI_TAPI.pdf
97
* attachment:Auerswald_COMmander_Basic2_Bedienhandbuch.pdf
98
* attachment:Auerswald_COMmander_Basic2_Checkliste.pdf
99
* attachment:Auerswald_COMmander_Basic2_Installationsanleitung.pdf
100
* attachment:Auerswald_COMmander_Basic2_Konfigurationshandbuch.pdf
101
* attachment:Auerswald_COMmander_Basic2_Konformitaetserklaerung.pdf
102
* attachment:Auerswald_COMmander_Basic2_Kurzanleitung.pdf
103
* attachment:Auerswald_COMmander_Basic2_Lizenzinformationen.pdf
104
* attachment:Auerswald_COMmander_Basic2_SDkarten_VMF.pdf
105
* attachment:Auerswald_COMmander_Basic2_Voicmail_Faxfunktion.pdf
Add picture from clipboard (Maximum size: 48.8 MB)