EWSD Create DLU » History » Revision 3
Revision 2 (nt2mku, 07/18/2024 12:43 PM) → Revision 3/6 (nt2mku, 07/18/2024 12:49 PM)
h1. EWSD Create DLU This guide describes the initial configuration of a new Digital Line Unit, connected via 2M E1 links (not a local DLU). 1st step: Create the DIU interface at the LTG. The LTG must be of configuration type B (for subscriber access). Example: LTG 0-8, DIU 3: <pre>CR LTU: LTG=0-8, LTU=3, TYPE=D30, APPLIC=CCSDLU;</pre> Note: DIU OST is automatically controlled by DLU OST. 2nd step: Create the DLU object. DLU object ID must be a multiple of 10 (10, 20, 30...). Example: DLU ID 10, Type DLUA, DIUDLU0 connected to DIU 3 at LTG 0-8: <pre>CR DLU: DLU=10, TYPE=DLUA, DLUC0=0-8-3-CCS0;</pre> 3rd step: Enable DC Converters in database: <pre> CONF DLUEQ: DLU=10, DCC=0-X,OST=MBL; CONF DLUEQ: DLU=10, DCC=0-X,OST=ACT; CONF DLUEQ: DLU=10, DCC=1-X,OST=MBL; CONF DLUEQ: DLU=10, DCC=0-X,OST=ACT; CONF DLUEQ: DLU=10, RGMG=X,OST=MBL; CONF DLUEQ: DLU=10, RGMG=X,OST=ACT; CONF DLUEQ: DLU=10, RGB=X,OST=MBL; CONF DLUEQ: DLU=10, RGB=X,OST=ACT; </pre> 4th step: Enable the DLU: <pre> CONF DLU: DLU=10, DLUC0=Y, OST=MBL; CONF DLU: DLU=10, DLUC0=Y, OST=ACT; </pre> 5th step: Configure and enable DLU modules. Example: SLMAFPBs in slot 0-0 to 0-7 (upper shelf) and 1-0 to 1-7 (lower shelf): <pre> CR DLUMOD: DLU=10, MOD=0-0&&0-7, TYPE=SLMAFPB; CR DLUMOD: DLU=10, MOD=1-0&&1-7, TYPE=SLMAFPB; CONF DLUMOD: DLU=10, MOD=0-0&&0-8, OST=MBL; CONF DLUMOD: DLU=10, MOD=0-0&&0-8, OST=ACT; CONF DLUMOD: DLU=10, MOD=1-0&&1-8, OST=MBL; CONF DLUMOD: DLU=10, MOD=1-0&&1-8, OST=ACT; </pre> Subscribers can now be created with parameter EQN=dluid-shelf-moduleslot-moduleport, e.g. EQN=10-0-0-0.