Project

General

Profile

ISDN POTS V5 Event Configuration » History » Version 9

laforge, 08/13/2023 05:19 PM

1 1 laforge
h1. ISDN POTS V5 Event Configuration
2
3
This page documents the configuration of our ISDN/POTS V5 access network for evens like the [[ISDN_at_CCC_Camp_2023]]
4
5
h2. Nokia EKSOS wooden racks
6
7
We currently have 3 setups using NOKIA EKSOS N20 racks.  They contain:
8
9
* Nokia EKSOS N20 shelf
10
** NCU (main CPU card) with V5/E1 and Q3/Ethernet interfaces
11
** any number of PSTN + ISDN BRI line cards (PSTN: 32 ports per card, ISDN: 16 ports per card)
12
** home-made unit for N20 shelf containing
13
*** nanopi R5S as Linux SoM
14
**** LAN1 port used for Q3 to NCU
15
**** WAN port used for uplink/back-haul\
16
**** special re-work applied internally to power the R5S from 12V DC without any USB-PD logic
17
*** icE1usb as USB-E1 interface towards the NCU
18
* 48V power supply (trimmed up to ~ 52V) for N20 shelf
19
* 12V power supply for fans + nanopi R5S
20
* 3x 120mm fan (1200 rpm) 12V mounted above N20 rack, airflow in upwards direction
21
* 50-port ISDN patch panel configured as
22
** ports 1-16: first 16 ports of PSTN card in slot U3
23
** ports 17-32: first 16 ports of PSTN card in slot U5
24
** ports 33-48: ISDN line card in slot U7
25
** ports 49-50: unused
26
27
h3. nanoPi R5S configuration
28
29
The nanoPI R5S is configured as follows:
30
* Plain Debian 12 installation using https://github.com/inindev/nanopi-r5
31
* osmo-e1d package from osmocom:nightly feed
32
** octoi client to connect to remote octoi server
33
* network config
34
** DHCP on the @wan@ port (back-haul/uplink)
35
** software-bridging (@q3br@) between @lan1@ and a @q3vx@ VXLAN device using group 3 on multicast group 239.1.1.1 on the @wan@ port
36 5 laforge
** static IP 192.168.2.1 on the @lan2@ port (local admin port)
37 1 laforge
38 2 laforge
h3. V5 configuration
39
40
Each AN is configured to have
41
* one V5 Interface (ID see below)
42
** one Link in each V5 interface (Link Id 1)
43 3 laforge
*** one C-Channel (0) on TS16 of Link 1
44 2 laforge
** Startup behaviour: V2
45
** Accelerated unblocking: Yes
46
** Disable Link ID Checking: Yes
47
** Startup during PSTN failure: No
48
49 7 jolly
|_.Name|_.Number|_.Q3 MAC|_.V5 Interface ID|_.R5S WAN MAC|_.R5S WAN IP|_.e1_line|
50
|Berlin|A108.2|00:40:43:f8:55:4a|7108|b4:22:52:84:71:26|10.20.23.145|4|
51 9 laforge
|Leipzig|A096.1|00:40:43:f8:a3:2a|7096|28:2c:44:56:31:22|10.20.23.116|5|
52 8 laforge
|Hamburg|A107.1|00:40:43:f9:a2:d8|7107|64:2e:f8:00:66:76|10.20.34.237|3|
53 2 laforge
54 1 laforge
h2. Siemens Fastlink
55
56
TBD
Add picture from clipboard (Maximum size: 48.8 MB)