Project

General

Profile

Wandel Goltermann DTX-1 » History » Version 2

laforge, 03/17/2023 09:56 AM

1 2 laforge
{{>toc}}
2
3 1 laforge
h1. Wandel Goltermann DTX-1
4
5
This is a [[Teletex]] test device designed + manufactured by Wandel+Goltermann.
6
7
It supports
8
* emulating a Teletex [[DTE]] towards a [[DCE]]
9
* emulating a [[DCE]] towards a [[DTE]]
10
* passive sniffing betwenen Telex [[DTE]] and [[DCE]]
11
* emulating a [[CSPDN__Datex-L]] switch between two Datex-L [[DTE]]
12
13
14
h2. EPROM images
15
16 2 laforge
* from one unit
17
** attachment:wg_x21_2009-9313.047.bin
18
** attachment:wg_x21_2009-9312.048.bin
19
** attachment:wg_x21_2009-9311.049.bin
20
* from another unit (older version?)
21
** attachment:wg_x21_2009-9311.010.bin
22
** attachment:wg_x21_2009-9312.019.bin
23
** attachment:wg_x21_2009-9313.018.bin
24
25
h2. Manuals
26
27
* attachment:dtx1-bedienungsanleitung.pdf
28
29
Service Manual and Annex are also available.
30
31
h2. Service / Repairs
32
33
h3. lack of display contrast
34
35
It has been observed that several units have problems with display contrast, even when the respective trimmer potentiometer is maxed out.  The cause is leaking electrolytic capacitors in the contrast voltage generation circuit, see pictures below.
36
37
{{thumbnail(20230302_143704.jpg)}}
38
{{thumbnail(20230302_143628.jpg)}}
39
{{thumbnail(20230302_143607.jpg)}}
40
41
After replacing the related capacitors C12, C13, C16 adn C17 on the LCD controller board, the original adjustment range of the contrast trimmer potentiometer could be restored.