Description
The OM2000 MO's will send us FAULT REPORT messages with various different bit-masks of faults:
- internal fault map class 1a
- internal fault map class 1b
- internal fault map class 2a
- external condition map class 1
- external condition map class 2
- replacement unit map
- for each of the maps
- iterate over each byte from offset 0..n
- iterate over each bit from 0..7
- print "%s Fault %u:%u\n" (name_of_map, byte_nr, bit_nr)
- iterate over each bit from 0..7
- iterate over each byte from offset 0..n
If we receive a fault report with all bytes in all maps set to zero, we shoulr print "All faults ceased" at the same WARNING level.