Description

This is more a documentation about a speciality of the Siemens P1 (Telekom D1 314) than a bug report.

  • If setting "ms max power" below 15 dBm, the phone will not attach.
  • If using dynamic MS power control, the phone stops transmitting uplink completely if instructed by the RAN to set power below 15 dBm. If control loop resets it back to >= 15 dBm, it continues transmitting.

Used RAN Software: Current OsmoBSC + OsmoBTS + Osmo-TRX-UHD from Gitea (incl. libosmocore etc.) + USRP B200.
SIM card: Sysmocom SJA2
P1 Software Version 18.06.93 09:58:48