Project

General

Profile

Auerswald COMmander Basic2 » History » Version 5

laforge, 02/20/2022 02:26 PM

1 4 laforge
h1. Auerswald COMmander Basic2
2 1 laforge
3 5 laforge
{{child_pages}}
4
5
6 1 laforge
@laforge bought an "Auerswald COMmander Basic 2" PBX for purposes of building a small ISDN/PSTN network.
7
8
It currently has the following cards installed:
9
1x E1 port (for connection to e.g. a E1 RAS server)
10 2 laforge
8x S0 ports (for ISDN cards, each S0 port can host two 64k dialup)
11 1 laforge
16x a/b ports (for analog modems)
12 5 laforge
8x Up0 ports (internal 2-wire interface, not directly usable without converters back to S0)
13 2 laforge
14
h2. Web configuration interface
15
16
The configuration interface of the PBX can be reached at http://192.168.0.24 via the built-in Ethernet port (just use any static IP address in the subnet 192.168.0.0/24 for the PC/browser side).  Username "admin", Password "123456".
17
18
h2. Dialing Plan
19
20
The telephone numbers are configured as four-digit numbers with the following keys:
21
* first digit is always '2' (other digits reserved for future extension with other PBX)
22
* second digit indicates daughterboard/module: (1-4)
23
* third digit indicates port within module (1-8)
24
* last digit is zero (analog) or 1-2 in case of BRI ports (for the two slots)
25
26
So a number like *2452* would mean:
27
* module number 4
28
* port 5 within that module (S0 bus)
29
* second 64k timeslot / participant on that bus
30
31
h2. Connections to 1U RJ45 panel
32
33
The PBX is wired to the 50-port RJ45 panel in the bottom 1U of the 6U enclosure
34
35
|_.RJ45|_.Type|_.Module|_.Port|_.Phone Number(s)|
36
|01|a/b|D|1|2110|
37
|02|a/b|D|2|2120|
38
|03|a/b|D|3|2130|
39
|04|a/b|D|4|2140|
40
|05|a/b|D|5|2150|
41
|06|a/b|D|6|2160|
42
|07|a/b|D|7|2170|
43
|08|a/b|D|8|2180|
44
|09|-|-|-|-|
45
|10|-|-|-|-|
46
|11|S0|B|1|2211, 2212|
47
|12|S0|B|2|2221, 2222|
48
|13|S0|B|3|2231, 2232|
49
|14|S0|B|4|2241, 2242|
50
|15|S0|B|5|2251, 2252|
51
|16|S0|B|6|2261, 2262|
52
|17|S0|B|7|2271, 2272|
53
|18|S0|B|8|2281, 2282|
54
|19|-|-|-|-|
55
|20|-|-|-|-|
56
|21|a/b|D|1|2310|
57
|22|a/b|D|2|2320|
58
|23|a/b|D|3|2330|
59
|24|a/b|D|4|2340|
60
|25|a/b|D|5|2350|
61
|26|a/b|D|6|2360|
62
|27|a/b|D|7|2370|
63
|28|a/b|D|8|2380|
64
|29|-|-|-|-|
65
|30|-|-|-|-|
66
|31|Up0|A|1|2411, 2412|
67
|31|Up0|A|1|2421, 2422|
68
|31|Up0|A|1|2431, 2432|
69
|31|Up0|A|1|2441, 2442|
70
|31|Up0|A|1|2451, 2452|
71
|31|Up0|A|1|2461, 2462|
72
|31|Up0|A|1|2471, 2472|
73
|31|Up0|A|1|2481, 2482|
74
|39|-|-|-|-|
75
|40|-|-|-|-|
76
|41|-|-|-|-|
77
|42|-|-|-|-|
78
|43|-|-|-|-|
79
|44|-|-|-|-|
80
|45|-|-|-|-|
81
|46|-|-|-|-|
82
|47|-|-|-|-|
83
|48|-|-|-|-|
84
|49|-|-|-|-|
85
|50|-|-|-|-|
86 3 laforge
87
88
h2. Documentation
89
90
* attachment:Auerswald_COMmander_Anleitung_fuer_Treiberinstallation_CAPI_TAPI.pdf
91
* attachment:Auerswald_COMmander_Anleitung_fuer_Treiberinstallation_CAPI_TAPI.pdf
92
* attachment:Auerswald_COMmander_Basic2_Bedienhandbuch.pdf
93
* attachment:Auerswald_COMmander_Basic2_Checkliste.pdf
94
* attachment:Auerswald_COMmander_Basic2_Installationsanleitung.pdf
95
* attachment:Auerswald_COMmander_Basic2_Konfigurationshandbuch.pdf
96
* attachment:Auerswald_COMmander_Basic2_Konformitaetserklaerung.pdf
97
* attachment:Auerswald_COMmander_Basic2_Kurzanleitung.pdf
98
* attachment:Auerswald_COMmander_Basic2_Lizenzinformationen.pdf
99
* attachment:Auerswald_COMmander_Basic2_SDkarten_VMF.pdf
100
* attachment:Auerswald_COMmander_Basic2_Voicmail_Faxfunktion.pdf
Add picture from clipboard (Maximum size: 48.8 MB)