Siemens FastLink » History » Version 24
WIMPy, 03/20/2024 04:52 PM
1 | 8 | laforge | {{>toc}} |
---|---|---|---|
2 | |||
3 | 14 | WIMPy | h1. Siemens FastLink / WideLink |
4 | 1 | laforge | |
5 | 24 | WIMPy | FastLink family product overview: attachment:"siemens_fastlink [2002].pdf" |
6 | |||
7 | 14 | WIMPy | Formerly FastLink, later WideLink is a family of devices forming a (primarily) [[PDH]] transport network technology by Siemens. It serves the following functionalities: |
8 | 7 | laforge | * transport of (leased) digital subscriber lines (typically 2 Mbps) over copper (1-pair G.SHDSL, 2-pair HDSL) and fiber (UG2 or proprietary single-fiber bi-directional system) |
9 | * add/drop multiplex of digital subscriber lines, e.g. from E1 (2 Mbps) to E3 (34 Mbps) |
||
10 | * optionally, add/drop multiplex up to STM-1 (electrical or optical) |
||
11 | * optionally, subscriber line termination of (leased or switched) POTS + ISDN lines ([[V5_Access_Multiplexers]]) |
||
12 | * optionally, cross-connect functionality |
||
13 | |||
14 | FastLink would typically be deployed as a _transport network_ by a telecom operator around the year 2000. They would deploy a number of multiplexers at various points of presence, from where they would run HDSL, HSDSL or optical lines to the respective customers that subscribed to a variety of digital services. Between the points of presence there would typically be a ring, either at the E3 or (probably more often) at the STM-1 level within the digital hierarchy. |
||
15 | 1 | laforge | |
16 | h2. Component Carriers |
||
17 | |||
18 | |_.Type|_.Part|_.Description| |
||
19 | |AMXLS||Access Multiplexer Shelf| |
||
20 | |CMXII||Cross-connect multiplexer II| |
||
21 | 21 | WIMPy | |[[FastLink_OMX16S|OMX16S]]|S42023-A841-xx|Optical Multiplexer OMX16 Shelf| |
22 | 1 | laforge | |OMXLS|S42023-A859-xx|Optical Multiplexer OMX16 Shelf| |
23 | 19 | WIMPy | |[[FastLink_ONU20|ONU 20]]|S32022-A768-A5|Small V5 AN Shelf (desktop / wall mount)| |
24 | 13 | WIMPy | |SMXLS||Synchronous Multiplexer SMX (STM-1/STM-4) Shelf + 8 LT*| |
25 | |SMXCS||Double Synchronous Multiplexer SMX (STM-1) Shelf| |
||
26 | 1 | laforge | |UMX2S||AMXC Shelf (AMX + Concentration)| |
27 | |UMXLS||Feeder Shelf| |
||
28 | |||
29 | h2. Components / Modules |
||
30 | |||
31 | |_.Type|_.Description|_.Usable in component carrier| |
||
32 | |LTCOH|HDSL (RTR/TM-03036, Tab 4, 1,168 Mbit/s, 2 pairs)|OMX2S2, OMX16S| |
||
33 | 9 | laforge | |[[FastLink_LT12CM|LT12CM]]|HDSL (ETR 152 1,168 MBit/s, 2 pairs)|OMX2S2, OMX16S| |
34 | |[[FastLink_LT22CM|LT22CM]]|HDSL (ETR 152,1,168 MBit/s, 2 pairs), dual|OMX2S2| |
||
35 | 12 | WIMPy | |RPSII|Remote Power Supply II|OMXS2, UMXLS| |
36 | 23 | WIMPy | |[[Fastlink_LTO-LT|LTO-LT]], [[Fastlink_LTO-NT|LTO-NT]]|2x E1 over Optical (8,704 Mbit/s, SM, single fiber)|OMXS2, OMX16S| |
37 | 1 | laforge | |LUC|G.703 long-haul|| |
38 | |LUCP|G.703 long-haul with phantom power|| |
||
39 | |LUCT|UK2 according to FTZ 1 TR 221 with phantom power|| |
||
40 | 9 | laforge | |[[FastLink_LUOT-A|LUOT-A]]|Optical (2,048 Bit/s, two fibers)|| |
41 | 15 | WIMPy | |OTSU|Optical Terminal Supervision Unit|| |
42 | 12 | WIMPy | |OTSU2M|Supervision and administration of local cards (except in UMXLS as slave of SUE) and remote equipment connected to them|OMXS2, OMX2S2, UMXLS, OMX16S, SMXLS| |
43 | 11 | WIMPy | |[[FastLink_SUE|SUE]]|Supervision and administration of local cards in UMXLS|UMXLS| |
44 | 20 | WIMPy | |[[FastLink_CUA|CUA]]|V5 multiplexer / Controller card for ONU 20|ONU 20| |
45 | 9 | laforge | |[[FastLink_OTRU36|OTRU36]]|Optical interface 36 Mbit/s (34Mbps F2an plus overhead)|OMX16S| |
46 | 1 | laforge | |DXMX34|Multiplexer from 16x 2 Mbit/s to 34 Mbit/s|| |
47 | |CUAII|AMXS central processor|AMXS| |
||
48 | |SUB162|Analog subscriber line card (16 port)|AMXS| |
||
49 | |LLA102/104|Analog leased line|AMXS| |
||
50 | |I8S0P|ISDN line card (S0, 8 port)|AMXS| |
||
51 | |IUL82|ISDN line card (Uk0 2B1Q, 8 port)|AMXS| |
||
52 | 17 | jolly | |IUL84|ISDN line card (Uk0 4B3T, 8 port)|AMXS| |
53 | 18 | WIMPy | |[[FastLink_I4UK2V5|I4UK2V5]]|ISDN line card (Uk0 2B1Q, 4 port)|ONU| |
54 | 15 | WIMPy | |ADM1e|Add Drop Multiplexer STM-1 electic|SMXLS, SMXCS| |
55 | 16 | WIMPy | |[[FastLink_ADM1o|ADM1o]]|Add Drop Multiplexer STM-1 optical|SMXLS, SMXCS| |
56 | 15 | WIMPy | |ADM4|Add Drop Multiplexer STM-4|SMXLS| |
57 | 16 | WIMPy | |[[FastLink_TC21E1|TC21E1]]|21 E1 expansion for ADM*|SMXLS, SMXCS| |
58 | 15 | WIMPy | |TC1E3|E3 expansion for ADM*|SMXLS, SMXCS| |
59 | |TC1STM1e|STM-1 expansion for ADM*|SMXLS, SMXCS| |
||
60 | 1 | laforge | |
61 | 8 | laforge | h2. CPE (Customer Premises Equipment) |
62 | 1 | laforge | |
63 | 22 | WIMPy | |_.Type|_.Description| |
64 | |NT12C|1x 2Mbit/1MBit (G.703)| |
||
65 | |[[Siemens_NT12CP|NT12CP]]|1x 2Mbit/1MBit G.703/G.704 or S2M (ISDN-PRA) over HDSL| |
||
66 | |[[Siemens_NT12CV|NT12CV]]|2x nx64k up to 2Mbit (V.35, V.36, X.21) over HDSL| |
||
67 | 10 | laforge | |[[Siemens TSU NT 22 O|NT22 O]]|2x 2Mbit (G.703) optical| |
68 | |NT22 OP|2x 2Mbit S2M (ISDN-PRA) optical| |
||
69 | |NT22 OV|2x nx64k up to 2Mbit (V.35, V.36, X.21) optical| |
||
70 | 6 | laforge | |NTU|128k or 64k (V.35, V.36, X.21)| |
71 | 22 | WIMPy | |[[Siemens_ULAF+_STU|STU]]|G.703 over SHDSL with modular customer interfaces| |
72 | 4 | laforge | |
73 | 8 | laforge | h2. Auto-generated list of child pages |
74 | 4 | laforge | |
75 | {{child_pages}} |