Bug #5101
closed
OsmoBSC# show trx
TRX 0 of BTS 0 is on ARFCN 246
Description: (null)
RF Nominal Power: 40 dBm, reduced by 0 dB, resulting BS power: 40 dBm
Radio Carrier NM State: Oper 'Enabled', Admin 'Unlocked', Avail 'OK'
RSL State: connected
Baseband Transceiver NM State: *Oper 'NULL'*, Admin 'Locked', Avail 'Power off'
E1 Signalling Link:
E1 Line 0, Type e1d: Timeslot 1, Mode RSL
E1 TEI 0, SAPI 0
TRX 1 of BTS 0 is on ARFCN 250
Description: (null)
RF Nominal Power: 40 dBm, reduced by 0 dB, resulting BS power: 40 dBm
Radio Carrier NM State: Oper 'Enabled', Admin 'Unlocked', Avail 'OK'
RSL State: connected
Baseband Transceiver NM State: *Oper 'NULL'*, Admin 'Locked', Avail 'Power off'
E1 Signalling Link:
E1 Line 0, Type e1d: Timeslot 4, Mode RSL
E1 TEI 1, SAPI 0
- Category set to Ericsson BTS
Note: In the ericsson OM2000 model a separate baseband transceiver MO does not exist. So this MO is just not updated and that is why its NULL. So after all this is just a display error.
- Status changed from New to In Progress
- % Done changed from 0 to 90
I think its best not to display the state of the bb_trxc MO. We also have exceptions for ip_access BTSs here, so we can also afford another exception for Ericsson BTSs as well.
https://gerrit.osmocom.org/c/osmo-bsc/+/28895 bts_trx_vty: do not print nmstate of bb_trxc mo
- Status changed from In Progress to Resolved
- % Done changed from 90 to 100
This is now resolved. We have decided not to hide the MO completely but rather prefix it with [virtual].