Bug #5101
closedShow BTS Channel Load on Ericsson BTS
100%
Description
On the RBS, the TRX NM State is always NULL.
This works around https://gerrit.osmocom.org/plugins/gitiles/osmo-bsc/+/refs/heads/keith/rbs_mo
to get the channel load showing up, but it is probably not the right patch.
Updated by keith about 3 years ago
OsmoBSC# show trx TRX 0 of BTS 0 is on ARFCN 246 Description: (null) RF Nominal Power: 40 dBm, reduced by 0 dB, resulting BS power: 40 dBm Radio Carrier NM State: Oper 'Enabled', Admin 'Unlocked', Avail 'OK' RSL State: connected Baseband Transceiver NM State: *Oper 'NULL'*, Admin 'Locked', Avail 'Power off' E1 Signalling Link: E1 Line 0, Type e1d: Timeslot 1, Mode RSL E1 TEI 0, SAPI 0 TRX 1 of BTS 0 is on ARFCN 250 Description: (null) RF Nominal Power: 40 dBm, reduced by 0 dB, resulting BS power: 40 dBm Radio Carrier NM State: Oper 'Enabled', Admin 'Unlocked', Avail 'OK' RSL State: connected Baseband Transceiver NM State: *Oper 'NULL'*, Admin 'Locked', Avail 'Power off' E1 Signalling Link: E1 Line 0, Type e1d: Timeslot 4, Mode RSL E1 TEI 1, SAPI 0
Updated by dexter almost 2 years ago
Note: In the ericsson OM2000 model a separate baseband transceiver MO does not exist. So this MO is just not updated and that is why its NULL. So after all this is just a display error.
Updated by dexter over 1 year ago
- Status changed from New to In Progress
- % Done changed from 0 to 90
I think its best not to display the state of the bb_trxc MO. We also have exceptions for ip_access BTSs here, so we can also afford another exception for Ericsson BTSs as well.
https://gerrit.osmocom.org/c/osmo-bsc/+/28895 bts_trx_vty: do not print nmstate of bb_trxc mo
Updated by dexter over 1 year ago
- Status changed from In Progress to Resolved
- % Done changed from 90 to 100
This is now resolved. We have decided not to hide the MO completely but rather prefix it with [virtual].